| EMPIRICAL SS DOSE EVENT RECORD |
| |
+--------------------------------------------------------------------+
MEANING: Specification of empirical steady-state dose for PREDPP
CONTEXT: $INPUT record and NONMEM data set
DISCUSSION:
With some systems, steady state cannot be computed by the usual meth-
ods requested by the SS data item. The Empirical steady state method
computes steady state by giving a large number of doses until the
state variables no longer change according to the SSTOL/SSATOL toler-
ance specified in $SUBROUTINES. The SS data item is not used. A neg-
ative value of ADDL requests the computation, and also specifies the
maximum number of doses (ABS(ADDL)+1). Interdose interval II is used
as usual.
Reserved variables ADDL_ACTUAL and ADDL_TIME and ADDL_TIMEDIFF are
given useful values.
(See Guide Introduction_7 "An Empirical Method of Achieving Steady
State")
REFERENCES: Guide Introduction_7