| ADVAN5 ADVAN7 |
| |
+--------------------------------------------------------------------+
MEANING: Choice of Pharmacokinetic Model for PREDPP
CONTEXT: Option of NM-TRAN $SUBROUTINES record
USAGE:
$SUBROUTINES [ADVAN=]ADVAN5
SAMPLE:
$SUBROUTINE ADVAN5
DISCUSSION:
ADVAN5 and ADVAN7 are routines in PREDPP's library which implement the
general linear model. The general linear model is used for systems in
which a drug is distributed between compartments according to linear
processes. ADVAN7 may be used when the eigenvalues of the rate con-
stant matrix are known to be real (which is true for many pharmacoki-
netic systems such as mammillary models). It is generally faster than
ADVAN5.
A $MODEL record is required to describe the compartments and their
attributes. The $PK record (or, if a user-supplied PK routine is
used, the $MODEL record) describes how the compartments are linked.
TRANS routines that may be used: TRANS1
Suppose there are m compartments in the system, including the output
compartment.
Basic PK parameters with TRANS1:
Kij (rate constant from compartment i to compartment j)
Ki0 (alternate name for Kim)
The letter T may be used as a separator between the two compart-
ment numbers, e.g., KiTj. The letter T is optional when there is
no ambiguity, but required when there are two possible interpre-
tations of the numbers that follow K. E.g., with 12 compart-
ments, K111 is ambiguous. It should be coded K1T11 or K11T1,
depending if it symbolizes the rate constant from compartment 1
to compartment 11 or from compartment 11 to compartment 1.
Additional PK parameters:
For each compartment n in the system (n=1, ..., m):
Sn - Scale for nth compartment
S0 - Alternate name for scale for output compartment
For each dosable compartment n in the system:
Fn - Bioavailability for nth compartment
Rn - Rate for nth compartment
Dn - Duration for nth compartment
ALAGn - Absorption lag for nth compartment
Other additional PK parameters:
F0 - Output fraction (also called Fm, FO)
XSCALE - Time scale
MTIME(i) - Model event times
Required PREDPP Library subroutines:
ADVAN5 - REXPON, RXSUBS
ADVAN7 - RRXPON, RXSUBS
Notes:
1 Analytical second derivatives used with the Laplacian method are
not obtained with ADVAN5 and ADVAN7. Numerical second deriva-
tives must be used.
REFERENCES: Guide VI Section VII.C.5, VII.C.7
REFERENCES: Guide IV Section V.C.4
Go to main index.
Created by nmhelp2html v. 1.0 written by Niclas Jonsson (Modified by AJB 5/2006,11/2007,10/2012)